FSPG Slab Edge Firestop

FSPG SEB Cavity Barrier comprises aluminium foil covered stone wool core. The integrated aluminium foil facings provides class ‘O’ rating and excellent resistance to smoke. The unique method of manufacture provides a resilient lateral compression required to ensure a tight fit.

FSPG Slab Edge Firestop

Key Product Points

  • Designed to be used in Ceiling Cavity, Slab Edge or Under Floor installations and heritage floor upgrades.

  • Ideal for Historical Building Upgrades.

  • Voids up to 300mm wide.

  • Air and Water Permeability Tested.

  • Moisture resistance.

  • Up to 120 minutes Fire Resistance.

  • Voids up to 590mm wide.

  • Free of halogens, asbestos, fibres and silica and is non toxic.

  • High speed installation.

  • Easy low maintenance system.

  • Excellent Acoustic Isolation Properties.

  • Suitable for use in irregular applications.

Certifications and Approvals

  • EN 1366-4

  • EN 13501-1, EN 13501-2

  • EN ISO 10140-2

  • BS 476 and Certifire CF5126

  • 0843-CPR-0331, ETA 16-0763

Key Installation Points

  • For good adhesion the surfaces of the building elements shall be free of any dust or grease and may need to be primed. On good, clean virgin concrete & masonry, no priming required.

  • Ensure that the aperture and services in question are tested with FSPG SEB Cavity Barrier and the site conditions are within the application specification.

  • FSPG SEB Cavity Barrier single components are simply laid end to end in either horizontal or vertical orientation and friction between the substrate to form a continuous barrier.

  • Cut the FSPG SEB unit oversized by 10mm to the width of the void. Install bracket into the FSPG SEB to at least mid-depth & in the middle of the section.

  • Evenly push the FSPG SEB unit into the void.

  • Brackets must be fixed to structure using non-combustible fixings.

  • Brackets should be positioned at 300mm and 700mm.

  • 2 bracket per length of 1200mm thus every 600mm.

  • The correct size units are placed in position end to end, ensuring joints are pushed tightly together.

  • To maintain integrity of the smoke barrier, joints must be taped with self-adhesive foil.

Tools Used for Installation

Image icon
DUST PAN & BRUSH
Image icon
SPATULA
Image icon
PENCIL & RULER
Image icon
PLASTIC SHEET
Image icon
TAPE MEASURE
Image icon
SAW
Image icon
BREAD KNIFE
Image icon
GREEN WIPE